home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 07311ctd.txt < prev    next >
Text File  |  1998-06-10  |  24KB  |  588 lines

  1.                          SECTION 07311
  2.  
  3.                  ASPHALT SHINGLE ROOFING SYSTEM
  4. NOTE ** CertainTeed fiberglass and organic asphalt
  5.         shingles.
  6. NOTE **
  7. NOTE ** This section is based on The CertainTeed Roofing
  8.         Collection(TM), the country's most extensive line
  9.         of fiberglass and organic asphalt shingles.
  10.         CertainTeed pioneered the concept of multi-layered
  11.         shingles, widely known today as "architectural"
  12.         shingles, and has led the industry in color
  13.         innovation with complex color blending technology
  14.         and the introduction of bold designer shingle
  15.         colors such as variegated reds, blues and greens.
  16. NOTE **
  17. NOTE ** For more information on CertainTeed products and
  18.         availability, or for the name of your local
  19.         CertainTeed representative, call or write:
  20. NOTE **     CertainTeed Architectural Support Group
  21. NOTE **     P.O. Box 860
  22. NOTE **     Valley Forge PA 19482
  23. NOTE **     Tel:  (800) 233-8990
  24. NOTE **     Fax:  (610) 341-7940
  25. NOTE **
  26. NOTE **
  27. NOTE ** The section must be edited to delete shingle types
  28.         and styles not required on a particular project.
  29. NOTE **
  30. NOTE ** SECTION 07311 - ASPHALT SINGLE ROOFING SYSTEM,
  31.         Copyright 1997, The Architect's Catalog, Inc.
  32.  
  33.  
  34. PART 1  GENERAL
  35.  
  36. 1.1  SECTION INCLUDES
  37.  
  38.     A.  Granule surfaced asphalt shingle roofing.
  39.  
  40.     B.  Moisture shedding underlayment, eave, valley and ridge
  41.         protection.
  42.  
  43.     C.  Associated metal flashing.
  44.  
  45. 1.2 RELATED SECTIONS
  46. NOTE ** Coordinate the sections listed below with actual
  47.         project requirements.
  48.  
  49.     A.  Section 06100 - Rough Carpentry:  Plywood Roof Sheathing.
  50.  
  51.     B.  Section 06150 - Wood Decking.
  52.  
  53.     C.  Section 07260 - Vapor Retarders.
  54.  
  55.     D.  Section _____ - _____________:  Attic space ventilation.
  56.  
  57.     E.  Section 07600 - Flashing and Sheet Metal.
  58.  
  59.     F.  Section 08620 - Unit Skylights.
  60.  
  61.     G.  Section _____ - _________________:  Chimney Flue.
  62.  
  63. 1.3 REFERENCES
  64. NOTE ** Delete references from the list below that are not
  65.         actually required by the text of the edited
  66.         section.
  67.  
  68.     A.  ASTM A 653/A 653M - Standard Specification for Steel
  69.         Sheets, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-
  70.         Coated (Galvannealed) by the Hot-Dip Process.
  71.  
  72.     B.  ASTM B 209 - Standard Specification for Aluminum and
  73.         Aluminum-Alloy Sheet and Plate.
  74.  
  75.     C.  ASTM B 370 - Standard Specification for Copper Sheet and
  76.         Strip for Building Construction.
  77.  
  78.     D.  ASTM D 224 - Standard Specification for Smooth-Surfaced
  79.         Asphalt Roll Roofing (Organic Felt).
  80.  
  81.     E.  ASTM D 225 - Standard Specification for Asphalt Shingles
  82.         (Organic Felt) Surfaced with Mineral Granules.
  83.  
  84.     F.  ASTM D 1970 - Standard Specification for Self-Adhering
  85.         Polymer Modified Bituminous Sheet Materials Used as Steep
  86.         Roofing Underlayment for Ice Dam Protection.
  87.  
  88.     G.  ASTM D 3018 - Standard Specification for Class A Shingles
  89.         Surfaced with Mineral Granules.
  90.  
  91.     H.  ASTM D 3161 - Standard Test Method for Wind-Resistance of
  92.         Asphalt Shingles (Fan-Induced Method).
  93.  
  94.     I.  ASTM D 3462 - Standard Specification for Asphalt Shingles
  95.         Made from Glass Felt and Surfaced with Mineral Granules.
  96.  
  97.     J.  ASTM D 4586 - Standard Specification for Asphalt Roof
  98.         Cement, Asbestos-Free.
  99.  
  100.     K.  ASTM D 4869 - Standard Specification for Asphalt-
  101.         Saturated Organic Felt Shingle Underlayment Used in
  102.         Roofing.
  103.  
  104.     L.  ASTM E 108 - Standard Test Methods for Fire Tests of Roof
  105.         Coverings.
  106.  
  107. 1.4 SUBMITTALS
  108.  
  109.     A.  Submit under provisions of Section 01300.
  110.  
  111.     B.  Product Data:  Provide manufacturer's printed product
  112.         information indicating material characteristics,
  113.         performance criteria, and product limitations.
  114.  
  115.     C.  Manufacturer's Installation Instructions:  Provide
  116.         published instructions that indicate preparation required
  117.         and installation procedures.
  118. NOTE ** Delete the paragraph below if no fiberglass
  119.         shingles are required.
  120.  
  121.     D.  Certificate of Compliance:  Provide Certificate of
  122.         Compliance from an independent laboratory indicating that
  123.         the asphalt fiberglass shingles made in normal production
  124.         meet or exceed the requirements of the following:
  125.         1.  ASTM E 108/UL 790 Class A Fire Resistance.
  126.         2.  ASTM D 3161/UL 997 Type I Wind Resistance.
  127.         3.  ASTM D 3462.
  128. NOTE ** Delete the following paragraph unless unusual
  129.         project conditions mandate shop drawings.
  130.  
  131.     E.  Shop Drawings:  Indicate specially configured metal
  132.         flashing, jointing methods and locations, fastening
  133.         methods and locations, and installation details, as
  134.         required by project conditions indicated.
  135.  
  136. 1.5 QUALITY ASSURANCE
  137.  
  138.     A.  Maintain one copy of manufacturer's application
  139.         instructions on project site.
  140.  
  141.     B.  Verify that manufacturer's label contains reference to
  142.         specified ASTM standards.
  143.  
  144. 1.6 ENVIRONMENTAL REQUIREMENTS
  145.  
  146.     A.  Take special care when applying WinterGuard Shingle
  147.         Underlayment and shingles when ambient and wind chill
  148.         temperatures are below 45 degrees F (7 degrees C).  Tack
  149.         WinterGuard in place if it does not adhere immediately to
  150.         the deck.
  151.  
  152. 1.7 EXTRA MATERIALS
  153.  
  154.     A.  Furnish under provisions of section 01700.
  155.  
  156.     B.  Provide ____ square feet (____ sq m) of extra shingles of
  157.         each color specified.
  158.  
  159. 1.8 WARRANTY
  160. NOTE ** Edit the following warranty requirements to conform
  161.         to shingle types specified.
  162.  
  163.     A.  Manufacturer's Warranty:  Furnish shingle manufacturer's
  164.         warranty for products of this section as follows:
  165.         1.  CertainTeed XT 25:  25 year warranty.
  166.         2.  CertainTeed XT 30:  30 year warranty.
  167.         3.  CertainTeed Hearthstead:  25 year warranty.
  168.         4.  CertainTeed Classic Horizon:  25 year warranty.
  169.         5.  CertainTeed New Horizon:  25 year warranty.
  170.         6.  Certainteed Highlands:  25 year warranty.
  171.         7.  CertainTeed Custom Sealdon 30:  30 year warranty.
  172.         8.  CertainTeed Landmark 40:  40 year warranty.
  173.         9.  CertainTeed Landmark 30:  30 year warranty.
  174.         10. CertainTeed Landmark 25:  25 year warranty.
  175.         11. CertainTeed Independence:  40 year warranty.
  176.         12. CertainTeed Hallmark:  30 year warranty.
  177.         13. CertainTeed Carriage House:  Lifetime warranty.
  178.         14. CertainTeed Grand Manor:  Lifetime warranty.
  179.  
  180.     B.  Warranty Supplement:  Provide manufacturer's supplemental
  181.         ("CertainTeed SureStart") warranty to cover labor and
  182.         materials in the event of a material defect for the
  183.         following period after completion of application of
  184.         shingles:
  185.         1.  First five years.
  186.         2.  First seven years (Carriage House).
  187.         3.  First ten years (Grand Manor).
  188.  
  189.     C.  Warranty Transferability Clause:  Make available to Owner
  190.         shingle manufacturer's standard option for transferring
  191.         warranty to a new owner.
  192.  
  193.  
  194. PART 2  PRODUCTS
  195.  
  196. 2.1 MANUFACTURER
  197.  
  198.     A.  Provide products manufactured by CertainTeed Corporation,
  199.         Architectural Support Group; P.O. Box 860, Valley Forge
  200.         PA 19482; ASD. Tel. (800) 233-8990, Fax. (610) 341-7940.
  201.  
  202.     B.  Substitutions  Not permitted.
  203.  
  204. 2.2 ASPHALT FIBERGLASS SHINGLES
  205. NOTE ** Delete shingle types not required for the building
  206.         project.
  207.  
  208.     A.  CertainTeed XT 25:  Conforming to ASTM D 3018 Type I -
  209.         Self-Sealing; UL Certification of ASTM D 3462, UL 997
  210.         Wind Resistance, and UL Class A Fire Resistance; glass
  211.         fiber mat base, ceramically colored/UV resistant mineral
  212.         surface granules across entire face of shingle, square
  213.         three-tab type.
  214. NOTE ** Retain one of the following two sub-paragraphs;
  215.         first is for East Coast Region, second is for Lake
  216.         Central and North Central Regions.
  217.         1.  Weight:  225 pounds per square (100 square feet) (11
  218.             kg/sq m).
  219.         2.  Weight:  230 pounds per square (100 square feet)
  220.             (11.2 kg/sq m).
  221. NOTE ** Retain one of the following two sub-paragraphs,
  222.         depending on color selection method.
  223.         3.  Color: ______________.
  224.         4.  Color:  As selected by Architect from manufacturer's
  225.             standards.
  226.  
  227.     B.  CertainTeed XT 30:  Conforming to ASTM D 3018 Type I -
  228.         Self-Sealing; UL Certification of ASTM D 3462, UL 997
  229.         Wind Resistance, and UL Class A Fire Resistance; glass
  230.         fiber mat base, ceramically colored/UV resistant mineral
  231.         surface granules across entire face of shingle, square
  232.         three-tab type.
  233. NOTE ** Delete one of the following two paragraphs.
  234.         1.  Weight:  250 pounds per square (100 square feet)
  235.             (12.2 kg/sq m).
  236.         2.  Weight:  245 pounds per square (100 square feet)
  237.             (11.9 kg/sq m).
  238. NOTE ** Retain one of the following two sub-paragraphs,
  239.         depending on color selection method.
  240.         3.  Color: ______________.
  241.         4.  Color:  As selected by Architect from manufacturer's
  242.             standards.
  243.  
  244.     C.  CertainTeed Classic Horizon:  Conforming to ASTM D 3018
  245.         Type I - Self-Sealing; UL Certification of ASTM D 3462,
  246.         UL 997 Wind Resistance, and UL Class A Fire Resistance;
  247.         glass fiber mat base, ceramically colored/UV resistant
  248.         mineral surface granules across entire face of shingle,
  249.         square three-tab type with random shadow line.
  250.         1.  Weight:  240 pounds per square (100 square feet)
  251.             (11.7 kg/sq m).
  252. NOTE ** Retain one of the following two sub-paragraphs,
  253.         depending on color selection method.
  254.         2.  Color: ______________.
  255.         3.  Color:  As selected by Architect from manufacturer's
  256.             standards.
  257.  
  258.     D.  CertainTeed New Horizon:  Conforming to ASTM D 3018 Type
  259.         I - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  260.         Wind Resistance, and UL Class A Fire Resistance; glass
  261.         fiber mat base, ceramically colored/UV resistant mineral
  262.         surface granules across entire face of shingle, no-cut-
  263.         out design with random shadow line.
  264. NOTE ** Retain one of the following two sub-paragraphs;
  265.         first is for Lake Central, second is for North
  266.         Central Region.
  267.         1.  Weight:  245 pounds per square (100 square feet)
  268.             (11.9 kg/sq m).
  269.         2.  Weight:  250 pounds per square (100 square feet)
  270.             (12.2 kg/sq m).
  271. NOTE ** Retain one of the following two sub-paragraphs,
  272.         depending on color selection method.
  273.         3.  Color: ______________.
  274.         4.  Color:  As selected by Architect from manufacturer's
  275.             standards.
  276.  
  277.     E.  CertainTeed Highlands:  Conforming to ASTM D 3018 Type I
  278.         - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  279.         Wind Resistance, and UL Class A Fire Resistance; glass
  280.         fiber mat base, ceramically colored/UV resistant mineral
  281.         surface granules across entire face of shingle, algae-
  282.         resistant; no-cut-out design with random shadow line.
  283. NOTE ** Highlands shingle recommended for East Coast
  284.         Region.
  285.         1.  Weight:  240 pounds per square (100 square feet)
  286.             (11.1 kg/sq m).
  287. NOTE ** Retain one of the following two sub-paragraphs,
  288.         depending on color selection method.
  289.         2.  Color: ______________.
  290.         3.  Color:  As selected by Architect from manufacturer's
  291.             standards.
  292.  
  293.     F.  CertainTeed Landmark 25:  Conforming to ASTM D 3018 Type
  294.         I - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  295.         Wind Resistance, and UL Class A Fire Resistance; glass
  296.         fiber mat base, ceramically colored/UV resistant mineral
  297.         surface granules across entire face of shingle; two-piece
  298.         laminated shingle.
  299.         1.  Weight:  245 pounds per square (100 square feet)
  300.             (11.9 kg/sq m).
  301. NOTE ** Retain one of the following two sub-paragraphs,
  302.         depending on color selection method.
  303.         2.  Color: ______________.
  304.         3.  Color:  As selected by Architect from manufacturer's
  305.             standards.
  306.  
  307.     G.  CertainTeed Landmark 30:  Conforming to ASTM D 3018 Type
  308.         I - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  309.         Wind Resistance, and UL Class A Fire Resistance; glass
  310.         fiber mat base, ceramically colored/UV resistant mineral
  311.         surface granules across entire face of shingle; two-piece
  312.         laminated shingle.
  313.         1.  Weight:  265 pounds per square (100 square feet)
  314.             (12.9 kg/sq m).
  315. NOTE ** Retain one of the following two sub-paragraphs,
  316.         depending on color selection method.
  317.         2.  Color: ______________.
  318.         3.  Color:  As selected by Architect from manufacturer's
  319.             standards.
  320.  
  321.     H.  CertainTeed Landmark 40:  Conforming to ASTM D 3018 Type
  322.         I - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  323.         Wind Resistance, and UL Class A Fire Resistance; glass
  324.         fiber mat base, ceramically colored/UV resistant mineral
  325.         surface granules across entire face of shingle; two-piece
  326.         laminated shingle.
  327.         1.  Weight:  300 pounds per square (100 square feet)
  328.             (14.6 kg/sq m).
  329. NOTE ** Retain one of the following two sub-paragraphs,
  330.         depending on color selection method.
  331.         2.  Color: ______________.
  332.         3.  Color:  As selected by Architect from manufacturer's
  333.             standards.
  334.  
  335.     I.  CertainTeed Independence:  Conforming to ASTM D 3018 Type
  336.         I - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  337.         Wind Resistance, and UL Class A Fire Resistance; glass
  338.         fiber mat base, ceramically colored/UV resistant mineral
  339.         surface granules across entire face of shingle; three-tab
  340.         type with random laminated tabs and random shadow line.
  341.         1.  Weight:  300 pounds per square (100 square feet)
  342.             (14.6 kg/sq m).
  343. NOTE ** Retain one of the following two sub-paragraphs,
  344.         depending on color selection method.
  345.         2.  Color: ______________.
  346.         3.  Color:  As selected by Architect from manufacturer's
  347.             standards.
  348.  
  349.     J.  CertainTeed Carriage House:  Conforming to ASTM D 3018
  350.         Type I - Self-Sealing; UL Certification of ASTM D 3462,
  351.         UL 997 Wind Resistance, and UL Class A Fire Resistance;
  352.         glass fiber mat base, ceramically colored/UV resistant
  353.         mineral surface granules across entire face of shingle,
  354.         algae-resistant; full two layer laminated  four-tab
  355.         shingle, scallop appearance.
  356.         1.  Weight:  355 pounds per square (100 square feet)
  357.             (17.3 kg/sq m).
  358. NOTE ** Retain one of the following two sub-paragraphs,
  359.         depending on color selection method.
  360.         2.  Color: ______________.
  361.         3.  Color:  As selected by Architect from manufacturer's
  362.             standards.
  363.  
  364.     K.  CertainTeed Grand Manor:  Conforming to ASTM D 3018 Type
  365.         I - Self-Sealing; UL Certification of ASTM D 3462, UL 997
  366.         Wind Resistance, and UL Class A Fire Resistance; glass
  367.         fiber mat base, ceramically colored/UV resistant mineral
  368.         surface granules across entire face of shingle, algae-
  369.         resistant; full two layer laminated  four-tab shingle,
  370.         plus additional random tabs.
  371.         1.  Weight:  430 pounds per square (100 square feet)
  372.             (21.0 kg/sq m).
  373. NOTE ** Retain one of the following two sub-paragraphs,
  374.         depending on color selection method.
  375.         2.  Color: ______________.
  376.         3.  Color:  As selected by Architect from manufacturer's
  377.             standards.
  378.  
  379. 2.3 ASPHALT ORGANIC SHINGLES
  380.  
  381.     A.  CertainTeed Custom Sealdon 30:  Conforming to ASTM D 225
  382.         Type III - Self-Sealing, UL 997 Wind Resistance, UL Class
  383.         C Fire Resistance; organic felt base, ceramically
  384.         colored/UV resistant mineral granules across entire face
  385.         of shingle, square three-tab type.
  386.         1.  Weight:  250 pounds per square (100 square feet)
  387.             (12.2 kg/sq m).
  388. NOTE ** Retain one of the following two sub-paragraphs,
  389.         depending on color selection method.
  390.         2.  Color: ______________.
  391.         3.  Color:  As selected by Architect from manufacturer's
  392.             standards.
  393.  
  394.     B.  CertainTeed Hearthstead:  Conforming to ASTM D 225 Type
  395.         III - Self-Sealing, UL 997 Wind Resistance, UL Class C
  396.         Fire Resistance; organic felt base, ceramically
  397.         colored/UV resistant mineral granules across entire face
  398.         of shingle, square four-tab type with random shadow
  399.         lines.
  400.         1.  Weight:  225 pounds per square (100 square feet)
  401.             (10.9 kg/sq m).
  402. NOTE ** Retain one of the following two sub-paragraphs,
  403.         depending on color selection method.
  404.         2.  Color: ______________.
  405.         3.  Color:  As selected by Architect from manufacturer's
  406.             standards.
  407.  
  408.     C.  CertainTeed Hallmark:  Conforming to ASTM D 225 Type III
  409.         - Self-Sealing, UL 997 Wind Resistance, UL Class C Fire
  410.         Resistance; organic felt base, ceramically colored/UV
  411.         resistant mineral granules across entire face of shingle,
  412.         three-tab type with random laminated tabs, and wood grain
  413.         appearance across exposed surfaces.
  414.         1.  Weight:  325 pounds per square (100 square feet)
  415.             (15.9 kg/sq m).
  416. NOTE ** Retain one of the following two sub-paragraphs,
  417.         depending on color selection method.
  418.         2.  Color: ______________.
  419.         3.  Color:  As selected by Architect from manufacturer's
  420.             standards.
  421.  
  422. 2.4 SHEET MATERIALS
  423. NOTE ** Delete paragraph below and installation
  424.         instructions in Part 3 if climatic conditions are
  425.         such that ice dam protection is not required.
  426.  
  427.     A.  Eave Protection:  CertainTeed "WinterGuard"; ASTM D 1970
  428.         sheet barrier of self-adhering rubberized asphalt
  429.         membrane shingle underlayment having high traction
  430.         surface, internal reinforcement, and "split" back plastic
  431.         release film; provide material with warranty equal in
  432.         duration to that of shingles being applied.
  433.  
  434.     B.  Underlayment:  ASTM D 4869 Type I, asphalt saturated
  435.         felt.
  436.  
  437. 2.5 FLASHING MATERIALS
  438.  
  439.     A.  Sheet Flashing:  ASTM A 361/A 361M; 26 gage (0.45 mm)
  440.         steel with minimum G115/Z350 galvanized coating.
  441.  
  442.     B.  Sheet Flashing:  ASTM B 209; 0.025 inch (0.63 mm) thick
  443.         aluminum, mill finish.
  444.  
  445.     C.  Sheet Flashing:  ASTM B 370; cold rolled copper; 16
  446.         ounces per square foot (0.55 mm); natural finish.
  447.  
  448.     D.  Bituminous Paint:  Acid and alkali resistant type; black
  449.         color.
  450.  
  451.     E.  Tinners Paint:  Color as selected by Architect to
  452.         coordinate with shingle color.
  453.  
  454. 2.6 ACCESSORIES
  455.  
  456.     A.  Nails:  Standard round wire type roofing nails, corrosion
  457.         resistant; hot dipped zinc coated steel, aluminum, or
  458.         chromated steel; minimum 3/8 inch (9.5 mm) head diameter;
  459.         minimum 11 or 12 gage (2.5 mm) shank diameter; shank to
  460.         be of sufficient length to penetrate through roof
  461.         sheathing or 3/4 inch (19 mm) into solid wood, plywood,
  462.         or non-veneer wood decking.
  463.  
  464.     B.  Plastic Cement: ASTM D 4586, asphalt roof cement.
  465.  
  466. 2.7 FLASHING FABRICATION
  467.  
  468.     A.  Form flashing to profiles indicated on Drawings, and to
  469.         protect roofing materials from physical damage and shed
  470.         water.
  471.  
  472.     B.  Form sections square and accurate to profile, in maximum
  473.         possible lengths, free from distortion or defects
  474.         detrimental to appearance or performance.
  475.  
  476.  
  477. PART 3  EXECUTION
  478.  
  479. 3.1 EXAMINATION
  480.  
  481.     A.  Verify existing site conditions under provisions of
  482.         Section 01700.
  483.  
  484.     B.  Verify that roof penetrations and plumbing stacks are in
  485.         place and flashed to deck surface.
  486.  
  487.     C.  Verify roof openings are correctly framed prior to
  488.         installing work of this section.
  489.  
  490.     D.  Verify deck surfaces are dry and free of ridges, warps,
  491.         or voids.
  492.  
  493. 3.2 ROOF DECK PREPARATION
  494.  
  495.     A.  Follow shingle manufacturer's recommendations for
  496.         acceptable roof deck materials.
  497.  
  498.     B.  Broom clean deck surfaces under eave protection and
  499.         underlayment prior to their application.
  500.  
  501. 3.3 INSTALLATION - EAVE ICE DAM PROTECTION
  502.  
  503.     A.  Place eave edge and gable edge metal flashing tight with
  504.         fascia boards.  Weather lap joints 2 inches (50 mm).
  505.         Secure flange with nails spaced 8 inches (200 mm) on
  506.         center.
  507.  
  508.     B.  Apply CertainTeed "WinterGuard" Waterproofing Shingle
  509.         Underlayment as eave protection in accordance with
  510.         manufacturer's instructions.
  511. NOTE ** Change dimension below to 48 inches or greater for
  512.         low slope roofs or  severe climatic conditions.
  513.  
  514.     C.  Extend eave protection membrane minimum 24 inches (610
  515.         mm) up slope beyond interior face of exterior wall.
  516.  
  517. 3.4 INSTALLATION - PROTECTIVE UNDERLAYMENT
  518. NOTE ** Delete 2 paragraphs below if all roof slopes are
  519.         greater than 4:12.  Otherwise, select either
  520.         complete WinterGuard underlayment or D 4869
  521.         underlayment in combination with eave ice dam
  522.         protection.  WinterGuard is an improved version of
  523.         standard underlayment, developed to resist standing
  524.         water held on a sloped roof at eaves and valleyus
  525.         by ice dams and to resist widn-driven water.
  526.         WinterGuard can be used to cover the entire roof
  527.         deck, rather than just eaves and valleys, when the
  528.         slope is so low (2-4:12) as to permit wind to drive
  529.         rain beneath the shingle.
  530.  
  531.     A.  Roof Slope Between 2:12 and 4:12:  Apply one layer of
  532.         "WinterGuard" over areas not protected by WinterGuard at
  533.         eaves, with ends and edges weather lapped minimum 6
  534.         inches (152 mm).  Stagger end laps each consecutive
  535.         layer.  Nail in place.
  536.  
  537.     B.  Roof Slope Between 2:12 and 4:12:  Apply two layers of D
  538.         4869 underlayment over areas not protected by WinterGuard
  539.         at eaves, with ends and edges weather lapped minimum 19
  540.         inches (480 mm).  Stagger end laps each consecutive
  541.         layer.  Nail in place.
  542.  
  543.     C.  Roof Slope 4:12 or Greater:  Install one layer asphalt
  544.         felt shingle underlayment perpendicular to slope of roof
  545.         and lap minimum 4 inches (100 mm) over eave protection.
  546.  
  547.     D.  Weather lap and seal watertight with plastic cement items
  548.         projecting through or mounted on roof.  Do not allow
  549.         solvent based cements to contact WinterGuard.
  550.  
  551. 3.5 INSTALLATION - VALLEY PROTECTION
  552.  
  553.     A.  For "closed-cut," "woven," and "open" valleys, first
  554.         place one ply of WinterGuard, minimum 36 inches (910 mm)
  555.         wide, centered over valleys.  Lap joints minimum 6 inches
  556.         (152 mm).  Follow instructions of shingle and
  557.         waterproofing membrane manufacturer.
  558.  
  559. 3.6 INSTALLATION - METAL FLASHING
  560.  
  561.     A.  Weather lap joints minimum 2 inches (50 mm).
  562.  
  563.     B.  Seal work projecting through or mounted on roofing with
  564.         plastic cement and make weathertight.
  565.  
  566. 3.7 INSTALLATION - ASPHALT SHINGLES
  567.  
  568.     A.  Install shingles in accordance with manufacturer's
  569.         instructions for product type and application specified.
  570.  
  571. 3.8 FIELD QUALITY CONTROL
  572.  
  573.     A.  Field inspection will be performed under provisions of
  574.         Section 01400.
  575.  
  576.     B.  Visual inspection of the Work will be provided by Owner.
  577.         If conditions are unacceptable, Owner will notify the
  578.         Architect.
  579.  
  580. 3.9 PROTECTION OF FINISHED WORK
  581.  
  582.     A.  Protect finished work under provisions of Section 01700.
  583.  
  584.     B.  Do not permit traffic over finished roof surface.
  585.  
  586.  
  587.                          END OF SECTION
  588.